 User Note: While great efforts have been taken to provide accurate and complete information on the pages of CPEP, please be aware that the information contained herewith is considered a work-in-progress for this thesis project. Modifications and changes related to the original building designs and construction methodologies for this senior thesis project are solely the interpretation of Caitlin Hanzel. Changes and discrepancies in no way imply that the original design contained errors of was flawed. Differing assumptions, code references, requirements, and methodologies have been incorporated into this thesis project; therefore, investigation results may vary from the original design.
 
 


 
 

Research

ASHRAE. 2007. ANSI/ASHRAE, Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality. American Society of Heating Refrigeration and Air Conditioning Engineers, Inc. Atlanta, GA 2007.

ASHRAE. 2007. ANSI/ASHRAE, Standard 90.1-2007. Energy Standard for Buildings Except Low-Rise Residential Buildings. American Society of Heating Refrigeration and Air Conditioning Engineers, Inc. Atlanta, GA. 2007

“Ceiling Radiant Cooling Panels as Viable Distributed Parallel Sensible Cooling Technology Integrated with DOAS.” Conroy, Christopher and Mumma, A. Stanley Ph.D., P.E
http://doas-radiant.psu.edu/7-5.pdf
 
“Designing a Dedicated Outdoor Air System with Ceiling Radiant Cooling Panels.” Jeong, Jae-Weon and Mumma, A. Stanley Ph.D., P.E “ ASHRAE Journal. October 2006. http://doas.psu.edu/Design_DOAS_CRCP_fall_06_Journal.pdf

“DOAS Supply Air Conditions”. Mumma, A. Stanley Ph.D., P.E, P.E. ASHRAE Journal. Spring 2008.
http://doas-radiant.psu.edu/IAQ_DOAS_SA_Cond_Sp_08.pdf

Egan, David M.  Architectural Acoustics. J. Ross Publishing, 2007.

“Energy Consequences of Increasing the Ventilation Air Flow Rate by 30% to Garner a LEED Green Point.”  Mumma, A. Stanley Ph.D., P.E
http://doas-radiant.psu.edu/30_percent_surplus_OA.pdf

Long, Marshall. Architectural Acoustics. New York: Elsevier Inc., 2006.

McQuiston, Parker, Spitler. Heating, Ventilation and Air Conditioning Analysis and Design.  Sixth Edition. John Wiley & Sons Inc. 2005

“Radiant Ceiling Cooling”. Dieckmann, John. ASHRAE Journal; Emerging Technologies. June 2004.
http://doas-radiant.psu.edu/Journal_Emerging_CRCP_04.pdf

“Safety and Comfort Using DOAS & Radiant Cooling Panel Systems”. Mumma, A. Stanley Ph.D., P.E. ASHRAE IAQ Applications. Winter 2002.
http://doas-radiant.psu.edu/IAQ5.pdf

The University of Oregon’s Solar Radiation Monitoring Laboratory website:
http://solardat.uoregon.edu/SolarData.html

 


 

 
     


 
 
 
     